禪譜產品分類
  • 相關公司(8)
Hello
Welcome to Zensor

Electrochemical Analyzer-Simulator , EIS Model
(Simulator of chemical sensor, Potentiostat, Impedance Analyzer)

ACIP100

  • Replaceable and Editable Chip
  • 5.0 Color touch panel
  • Simulation of chemical sensor for off-line use
  • Electrochemical & AC Impedance analyzer

Electrochemical Analyzer-Simulator , EIS Model
(Simulator of chemical sensor, Potentiostat, Impedance Analyzer)

ACIP100

  • Replaceable and Editable Chip
  • 5.0 Color touch panel
  • Simulation of chemical sensor for off-line use
  • Electrochemical & AC Impedance analyzer

  • Items of electrochemical
                                potentiostat/simulator-Zensor R&D-ECAS100
    Button and interface of electrochemical
                                potentiostat/simulator-Zensor R&D-ECAS100

    • Complete electrochemical functions

      • • CV (Cyclic Voltammetry)

      • • IT (Amperometry)

      • • AC Imprdance(ACIP)

      • • Impedance-Time (IMPT)

      • • Impedance-Potential(IMPE)

  • Multiple Ports

    Traditional electrode and Screen Printed Electrode are available

     multiple connector & cable of
                                        electrochemical
                                        potentiostat/simulator/AC
                                        impendence/EIS-Zensor R&D-ACIP 100
     multiple connector & cable of
                                        electrochemical
                                        potentiostat/simulator/AC
                                        impendence/EIS-Zensor R&D-ACIP 100
     multiple connector & cable of
                                        electrochemical
                                        potentiostat/simulator/AC
                                        impendence/EIS-Zensor R&D-ACIP 100
  • Off-line Mode is Available for Used Alone

    5.0 Color touch panel
    used alone without the PC

    Off-line use of electrochemical
                                      potentiostat/simulator/AC
                                      impendence/EIS-Zensor R&D-ACIP 100
  • Simulation-Chip Test Mode

    Edit program freely, replaceable chip

    Whether you are developing a prototype of a product or creating a standard test method, you can use our simulation function.You can edit electrochemical scanning method,detection duration,enrichment time, correction curve freely and then burn these to the chip, you can use touch panel to control the test without computer, and read the results directly on the screen.
    replaceable
                                      & editable chip of electrochemical
                                      potentiostat/simulator/AC
                                      impendence/EIS-Zensor R&D-ACIP 100
    • Simulation-Chip-icon08

      It only takes 4 steps to complete process editing
      (Procedure / Data analysis / Concentration transfer / Action to burn-in)

    • Simulation-Chip-icon09

      Each ECA methods can be edited interchangeably
      (CV / IT / EIS-AC Impendance)

    • Simulation-Chip-icon10

      Match up the sample injection status for interchangeable editing
      (Wating for sample / Wating for second / Wating for trigger button)

  • Great for Products Development

  • Develope medical device- glucose meter

    Develope measuring equipment-pH meter

Main Function(A)ECA(ElectroChemical Analyer) with On-line.
(B)ECAS(ElectroChemical Analytical Simulator) with Off-line
Charateristic(A)ECA/ECAS mode change
(B)ECAS for applocation in real sample testing with off-line
(C)Flexible edit program for operation of ECAS with off-line
(D)5.0 color touch panel for display the result of ECAS with off-line
Electrochemical
Methods
(A)cyclic Voltammetry(CV)
(B)amperometry(IT)
(C)AC Impedance(ACIP)
(D)Impedance-Time(IMPT)
(E)Impedance-Potential(IMPT)
Range(A)Voltage range: +2~-2(V)
(B)Current range: 10-3~10-9(A)
(C)Data records number in ECAS mode: 100 data records
(D)ACIP Frequency: 10mHz-1KHz
Operation systemwindows XP above
Power input5V, 1600mA
Sensor connector color(A)Green color-Working electrode(WE)
(B)Red color-Counter electrode(CE)
(C)White color - Reference electrode(RE)
Size of Machine193(L) x 112(W) x 43(H) mm

Which potentiostat best suitable your needs?

ECWP100singleECWP100plusMCP100ECAS100ACIP100
wirelessWirelessUSB poweredUSB and battery powered + Offline useUSB and battery powered + Offline use
---Simulation(editable chip)Note.1Simulation(editable chip)Note.1
SPE availabelSPE availabelSPE availabelSPE availabelSPE availabel
3 clips connector optionally available3 clips connector optionally available3 clips connector available3 clips connector available3 clips connector available
Single-channelMaximum 8 channelsChannels 2-8 are availableSingle-channelSingle-channel
Need PCNeed PCNeed PC5.0 touch panel5.0 touch panel
CV/LSV/SWV/DPV/IT/OCPCV/LSV/SWV/DPV/IT/OCPCV/IT/OCPCV/LSV/SWV/DPV/IT/OCPCV/IT/OCP
----ACIP
----IMPT
----IMPE
+2~-2V+2~-2V+2~-2V+2~-2V+2~-2V
10-3~10-9A10-3~10-9A10-2~10-10A10-2~10-10A10-2~10-10A
Detail-InfoDetail-InfoDetail-InfoDetail-InfoDetail-Info

Note1:Simulation function-The test steps can be burned into a replaceable chip, so a large number of test samples can be tested offline, and the required values can be read directly on the panel .That will simulate the process of product model development.

Learn More? Get Free Quatation?

Have a chat with Zensor expert